Top Ad unit 728 × 90

random

How to Estimating Diameter Size of Distilation Tower

Oil and gas refinery facility - There are so many question came from IndustriMigas follower about how to estimating diameter size of distilation tower at refinery production facilities. Estimating diameter size of distillation tower in oil and gas refinery facility is the most important step to design a distillation tower. Detail steps of estimating diameters size of distillation coloumn are :
[post_ad]
How to calculate distillation tower diameter
Illustration Distillation Tower, doc. arb.ca.gov

Calculate Liquid – Vapor Flow Parameter


To calculate liquid – vapour flow parameter (FLV) using this formula:
Liquid - Vapor Flow Parameter Formula

Where :
WL    = mass rate liquid per unit area, lb/ hr
Wv    = mass rate vapor per unit area, lb / hr
ρv     = density vapor ,lb/ft3
ρL     = density liquid, lb/ft3

Calculate Corrected CSB


To calculate Corrected CSB using this formula:
Calculate Corrected CSB formula

Where :

σ      = actual interfacial tension (mN/m2)

Calculate Vapor Velocity (UN) 

To calculate vapor velocity using this formula:
Calculate vapor velocity


Calculate Net Area

 To calculate net area of distillation tower using this formula :

Net Area of distilation tower

Where :

AN     = Net area for vapor flow

CFS   = volumetric rate of vapor, ft3/sec

FF        = floading factor , umumnya diambil 80 % atau 0.8



Calculate Total Tower Area (AT)


 To calculate total tower area of distillation tower using this formula :
Total tower area of distilation tower
down comer area of distilation tower
total tower area of distilation tower

Where :

AD  = downcomer area, ft2.

Calculate Diameter Tower (DT)


 After calculate all of parameter above we can calculate Diameter of Distilation Tower using this formula :
Diameter tower formula of distilation tower (refinery facility)

Maximum clear liquid velocities in down comer*.

Foaming Tendency
Example
Clear Liquid Velocity, ft/sec
Spacing
18 in
24 in
30 in
Low
Low press. (<100 psia).Light HC. Stabilizer. air-water simulator
0.4-0.5
0.5-0.6
0.6-0.7
Medium
Oil system. crude oil distillation. mid press. (100-300 psia) HC
0.3-0.4
0.4-0.5
0.6-0.7
High
Amine. glycerine. glycols. high press. (>300 psia). light HC
0.2-0.25
0.2-0.25
0.2-0.3

Note : * Source “Distillation Operation. Henry Z. Kister”
How to Estimating Diameter Size of Distilation Tower Reviewed by Djoernalist on 9:45 AM Rating: 5

1 comment:

  1. Hello, my name is Aisha Nayla, prey to fraud at the hands of fake lenders. I lost around Rp300,000,000 because I needed a large capital of Rp300,000,000,000. I almost died, I had no place to go. my trade was destroyed, and in the process I lost my child and mother. I can't stand this incident anymore. Last week I met an old friend who introduced me to a good mother, Mrs Christabel Missan Loan Investment Company, which finally helped me get loan of  Rp500,000,000,000 loan

     Good mother, I want to take this opportunity to express my gratitude, and may God continue to bless the good mother Christabel Missan and my friend. I also want to use this opportunity to give advice to fellow Indonesians, that there are a lot of fraudsters there, so if you need a peace and security loan and anyone who needs an urgent loan should be quick, contact Christabel Missan via email christabelloancompany@gmail.com
    You can still contact the mother whatsApp number +15614916019

    You can also contact me by email: (aishanaylad@gmail.com). And you can still contact my friend who introduced me to a good mother loan company, Lady Liliyana, email: liliyanabasuki@gmail.com if you are in doubt. help him the only person who can be trusted and can be trusted.

    ReplyDelete

Thank you for visit and read this post. Share this post if you like it.
Leave your comment on this text box

All Rights Reserved by IndustriMigas | #1 Oil and Gas Blog © 2019 - 2020
Powered By Blogger, Designed by Sweetheme

Contact Form

Name

Email *

Message *

www.industrimigas.com. Powered by Blogger.